Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Center for Computational Science & e-Systems
JAEA-Evaluation 2021-001, 66 Pages, 2021/11
Research on advanced computational science for nuclear applications, based on "the plan to achieve the mid- and long-term goal of the Japan Atomic Energy Agency", has been performed by Center for Computational Science & e-Systems (CCSE), Japan Atomic Energy Agency. CCSE established a committee consisting of external experts and authorities which does research evaluation and advice for the assistance of the future research and development. This report summarizes the results of the R&D performed by CCSE in FY2020 (April 1st, 2020 - March 31st, 2021), the results expected at the end of the 3rd mid and long-term goal period, and the evaluation by the committee on them.
Center for Computational Science & e-Systems
JAEA-Evaluation 2020-002, 37 Pages, 2020/12
Research on advanced computational science for nuclear applications, based on "the plan to achieve the mid and long term goal of the Japan Atomic Energy Agency", has been performed at Center for Computational Science & e-Systems (CCSE), Japan Atomic Energy Agency. CCSE established a committee consisting of outside experts and authorities which does research evaluation and advice for the assistance of the future research and development. This report summarizes the results of the R&D performed at CCSE in FY2019 (April 1st, 2019 - March 31st, 2020) and the evaluation by the committee on them.
Sakaba, Nariaki; Nakagawa, Shigeaki; Furusawa, Takayuki; Tachibana, Yukio
JAERI-Tech 2004-045, 67 Pages, 2004/04
Safety demonstration tests using the HTTR are now underway in order to verify the inherent safety features and to improve the safety design and evaluation technologies for HTGRs, as well as to contribute to research and development for the VHTR, which is one of the Generation IV reactors. In the safety demonstration tests, the coolant flow reduction test by tripping one or two out of three gas circulators is being performed between FY2002 and FY 2005 and by tripping all the three gas circulators will be conducted after FY2006. This paper describes the structural integrity assessment of the primary pressurised water cooler after one and two gas circulators run down. Also, the possibility of natural convection in the primary coolant after all the three gas circulator stopped was evaluated by the operation data of the reactor-scram test performed during the rise-to-power tests.
*; *;
JAERI-Data/Code 96-031, 53 Pages, 1996/11
no abstracts in English